ECAM ELEC page
Back to ECAM System Display Overview
Number | Name | Variation | Meaning |
---|---|---|---|
1 | Battery | White color | The battery is within normal operating range. |
Amber color | There is a BAT FAULT alert, or the battery voltage or battery current is amber. | ||
2 | Battery voltage | Green color | The battery voltage is within normal operating range. |
Amber color | The battery voltage is less than 25 Volts or greater than 31 Volts. | ||
3 | Battery current | Green color | The battery current is within normal operating range. |
Amber color | The battery current is discharging at greater than 5 Ampere. | ||
4 | Battery charge and discharge | Green Left arrow | The battery contactor is closed, and the charging current is greater than 1 Ampere. |
Amber right arrow | The battery contactor is closed, and the discharge current is greater than 1 Ampere. | ||
Green line | The battery contactor is closed, and the current is less than 1 Ampere. | ||
No line | The battery contactor is open. | ||
5 | DC Battery | Green color | The DC Battery voltage is within normal operating range. |
Amber color | The DC Battery voltage is less than 25 volts. | ||
6 | Bus bar | Green color | The corresponding bus bar is in normal operations. |
Amber color | The corresponding bus bar is not powered. | ||
Amber SHED | The AC or the DC SHED ESS BUS is in shed mode. | ||
7 | TR | White color | The TR parameters are in normal operations. |
Amber color | The TR voltage is in amber, or the TR current is in amber. | ||
8 | TR Voltage | Green color | The TR voltage is within normal operating range. |
Amber color | The TR voltage is less than 25 Volts or greater than 31 Volts. | ||
9 | TR current | Green color | The TR current is within normal operating range. |
Amber color | The TR current is less than 5 Ampere. | ||
10 | ESS TR | Hidden | The essential TR is open. |
Shown | The essential TR is closed. | ||
11 | EMER GEN | Hidden | The EMER GEN line contractor is open |
Shown | The EMER GEN line contractor is closed. | ||
12 | GEN | White color | The corresponding generator is in normal operations |
Amber color | The corresponding generator has either a load legend in amber, a voltage legend in amber, or a frequency legend in amber. | ||
13 | GEN load | Green color | The corresponding generator load is within normal operating range. |
Amber color | The corresponding generator load is greater than 100%. | ||
14 | GEN Voltage | Green color | The corresponding generator voltage is within normal operating range. |
Amber color | The corresponding generator voltage is less than 110 Volts, or greater than 120 Volts. | ||
15 | GEN frequency | Green color | The corresponding generator frequency is within normal operating range. |
Amber color | The corresponding generator frequency is less than 390 Hertz, or greater than 410 Hertz. | ||
16 | APU GEN | White APU GEN | Remains on the display regardless of the position of the APU GEN switch. |
Amber APU GEN and White OFF | The APU Master switch is ON, but the APU GEN is off. | ||
White and Green color table | Same as a generator indications. | ||
17 | External Power Indication | Hidden | The external power is not available |
White color | The external power parameters are in normal operations. | ||
Amber color | The external power voltage or frequency is in amber color. | ||
18 | External Power voltage | Green color | The external power voltage is within normal operating range. |
Amber color | The external power voltage is less than 110 Volts, or greater than 120 Volts. | ||
19 | External Power Frequency | Green color | The external power frequency is within normal operating range. |
Amber color | The external power frequency is less than 390 Hertz, or greater than 410 Hertz. | ||
20 | IDG Legend | White color | The IDG is in normal operations. |
Amber color | The oil outlet temperature is greater than 180°C, the oil pressure is too low, or the IDG becomes disconnected. | ||
21 | DISC/LO PR | Hidden | The IDG is connected. |
Amber DISC | The IDG is disconnected | ||
Amber LO PR | An IDG low pressure is detected on the associated engine. | ||
22 | Oil outlet temperature | Green color | The oil outlet temperature is within normal operating range. |
Amber color | The oil outlet temperature is greater than 180 °C. | ||
Pulsion | The oil outlet temperature is greater than 147°C, but less than 180°C. |
Last update: September 20, 2021